filter
search
It looks like you're in North America.
View North American standard English: 120-277V | UL
Sustainability
Products
New
Indoor
Outdoor
Intelligent Light Solutions
iGuzzini Living
iGuzzini Echoes
Bespoke
Code Finder
Projects
Project Gallery
Light is Back
Lighthinking
About
Magazine
Annual
Events
News
News
Events
Light Application
Corporate
Working at iGuzzini
Downloads
Newsletter
Knowledge Base (login required)
Contacts
Corporate
menu
Code Finder
Global
Region & Language
Global
USA / Canada
China
Global standard
220V-240V/50Hz | ENEC
Select a language:
English
French
German
Italian
Spanish
North American standard
120-277V | UL
Select a language:
English
French
China standard
220V-240V/50Hz | CCC
Select a language:
English
Global
USA / Canada
China
Technical Region
English
French
German
Italian
Spanish
Prefered Language
English
French
Prefered Language
English
Prefered Language
Update
iGuzzini
Search
Your search returned no results
Code Finder
Find the product codes you need by filtering from our whole product range.
Find Codes
Code Finder
Cylindrical pole
belongs to
Cylindrical pole - buried / with plate
Reset data
1289
Updating Product Data...
Downloads updated
updated
Product Information updated
updated
Accessories list updated
updated
Photometric configuration only available on screens above 1024px
updated
Cylindrical pole - Cylindrical pole with plate - Total H 7000mm - pole diameter Ø120mm
Product Information
Size (mm): ø120x7000, Weight (kg): 92.70
Base diameter (mm): 120.00
Height above ground (mm): 7000.00
Thickness (mm): 4.00
Hatch width (mm): 95.00
Hatch height (mm): 310.00
Available colours
15
Grey
Technical Specifications
Installation information
Installation: The pole is applied by connecting the welded plate to the anchor plate, which is made of EN10130 DC01 (ex Fe P01 UNI 5866) hot galvanised steel, and the anchoring bolts prevent it from moving. The fixing plate and relative anchoring bolts (code 0453) are not included with the pole accessories. Upon request, a grey pole base plate can be used (code 1841), consisting of two parts which can be joined together, made of die-cast aluminium, 420 mm in diameter and 122 mm high. The element can be customised with cast embossed text.
Wiring: The access slot is at a distance of 1000 mm from the pole base, and measures 310x95 mm. The access cover is made of die-cast aluminium and is mounted flush with the pole on the side perpendicular to the roadside. The cover comes complete with a gasket that ensures a seal when closed with the large triangular key (9 mm key side). The power cable enters through the hole in the pole base. There is a tropicalised steel earthing insert secured inside the pole near the access cover. The maximum earth cable section is 16 mm2.
Accessories (
3
)
Accessory Type
Accessory Type
Accessory Type
Mounting accessories
Wiring components
0246
Spanner for inspection lid
00
Indeterminate
0453
Plate w/bolts
00
Indeterminate
1863
Terminal board
00
Indeterminate
This accessory can be used with the following product codes (982)
Agorà
See Overview
Agorà ø313mm compact
64 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
4425
53.5
SS 4.3°
4000
80
DALI-2
ø313x363
ET07
New
4050
53.5
SS 4.3°
3000
80
DALI-2
ø313x363
ET02
New
3825
53.5
SS 4.3°
2700
80
DALI-2
ø313x363
ES97
New
3037.5
53.5
SS 4.3°
2200
80
DALI-2
ø313x363
ES94
New
7469
63.3
S 16°
4000
80
DALI-2
ø313x363
ET08
New
7084
63.3
S 16°
3000
80
DALI-2
ø313x363
ET03
New
6814.5
63.3
S 16°
2700
80
DALI-2
ø313x363
ES98
New
7372
63.3
F 30°
4000
80
DALI-2
ø313x363
ET09
New
6992
63.3
F 30°
3000
80
DALI-2
ø313x363
ET04
New
6726
63.3
F 30°
2700
80
DALI-2
ø313x363
ES99
New
5928
63.3
F 30°
2200
80
DALI-2
ø313x363
ES95
New
7178
63.3
WF 50°
4000
80
DALI-2
ø313x363
ET10
New
6808
63.3
WF 50°
3000
80
DALI-2
ø313x363
ET05
New
6549
63.3
WF 50°
2700
80
DALI-2
ø313x363
ET00
New
6014
63.3
WW
4000
80
DALI-2
ø313x363
ET11
New
5704
63.3
WW
3000
80
DALI-2
ø313x363
ET06
New
5487
63.3
WW
2700
80
DALI-2
ø313x363
ET01
New
4836
63.3
WW
2200
80
DALI-2
ø313x363
ES96
Complete with power supply.
These codes can be used at a maximum environment temperature of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
5550
71.1
SS 4.3°
4000
80
DALI-2
ø313x363
ET25
New
5062.5
71.1
SS 4.3°
3000
80
DALI-2
ø313x363
ET20
New
4800
71.1
SS 4.3°
2700
80
DALI-2
ø313x363
ET15
New
3787.5
71.1
SS 4.3°
2200
80
DALI-2
ø313x363
ET12
New
9625
86.9
S 16°
4000
80
DALI-2
ø313x363
ET26
New
9124.5
86.9
S 16°
3000
80
DALI-2
ø313x363
ET21
New
8778
86.9
S 16°
2700
80
DALI-2
ø313x363
ET16
New
9500
86.9
F 30°
4000
80
DALI-2
ø313x363
ET27
New
9006
86.9
F 30°
3000
80
DALI-2
ø313x363
ET22
New
8664
86.9
F 30°
2700
80
DALI-2
ø313x363
ET17
New
7676
86.9
F 30°
2200
80
DALI-2
ø313x363
ET13
New
9250
86.9
WF 50°
4000
80
DALI-2
ø313x363
ET28
New
8769
86.9
WF 50°
3000
80
DALI-2
ø313x363
ET23
New
8436
86.9
WF 50°
2700
80
DALI-2
ø313x363
ET18
New
7750
86.9
WW
4000
80
DALI-2
ø313x363
ET29
New
7493.94
86.9
WW
3000
80
DALI-2
ø313x363
ET24
New
7068
86.9
WW
2700
80
DALI-2
ø313x363
ET19
New
6262
86.9
WW
2200
80
DALI-2
ø313x363
ET14
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
5967.5
50.8
S 16°
4000
80
DALI-2
ø313x363
N466
New
5659.5
50.8
S 16°
3000
80
DALI-2
ø313x363
N462
New
5467
50.8
S 16°
2700
80
DALI-2
ø313x363
N458
New
5890
50.8
F 30°
4000
80
DALI-2
ø313x363
N467
New
5586
50.8
F 30°
3000
80
DALI-2
ø313x363
N463
New
5396
50.8
F 30°
2700
80
DALI-2
ø313x363
N459
New
4750
50.8
F 30°
2200
80
DALI-2
ø313x363
N456
New
5735
50.8
WF 50°
4000
80
DALI-2
ø313x363
N468
New
5439
50.8
WF 50°
3000
80
DALI-2
ø313x363
N464
New
5254
50.8
WF 50°
2700
80
DALI-2
ø313x363
N460
New
4805
50.8
WW
4000
80
DALI-2
ø313x363
N469
New
4557
50.8
WW
3000
80
DALI-2
ø313x363
N465
New
4402
50.8
WW
2700
80
DALI-2
ø313x363
N461
New
3875
50.8
WW
2200
80
DALI-2
ø313x363
N457
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
8008
71.7
S 16°
4000
80
DALI-2
ø313x363
N480
New
7584.5
71.7
S 16°
3000
80
DALI-2
ø313x363
N476
New
7315
71.7
S 16°
2700
80
DALI-2
ø313x363
N472
New
7904
71.7
F 30°
4000
80
DALI-2
ø313x363
N481
New
7486
71.7
F 30°
3000
80
DALI-2
ø313x363
N477
New
7220
71.7
F 30°
2700
80
DALI-2
ø313x363
N473
New
6384
71.7
F 30°
2200
80
DALI-2
ø313x363
N470
New
7696
71.7
WF 50°
4000
80
DALI-2
ø313x363
N482
New
7289
71.7
WF 50°
3000
80
DALI-2
ø313x363
N478
New
7030
71.7
WF 50°
2700
80
DALI-2
ø313x363
N474
New
6448
71.7
WW
4000
80
DALI-2
ø313x363
N483
New
6107
71.7
WW
3000
80
DALI-2
ø313x363
N479
New
5890
71.7
WW
2700
80
DALI-2
ø313x363
N475
New
5208
71.7
WW
2200
80
DALI-2
ø313x363
N471
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
Agorà ø368mm compact
28 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
7687.5
89.3
SS 4.3°
4000
80
DALI-2
ø368x421
ET92
New
6975
89.3
SS 4.3°
3000
80
DALI-2
ø368x421
ET88
New
6637.5
89.3
SS 4.3°
2700
80
DALI-2
ø368x421
ET84
New
5212.5
89.3
SS 4.3°
2200
80
DALI-2
ø368x421
ET82
New
15015
128.3
S 16°
4000
80
DALI-2
ø368x421
ET93
New
14245
128.3
S 16°
3000
80
DALI-2
ø368x421
ET89
New
13706
128.3
S 16°
2700
80
DALI-2
ø368x421
ET85
New
14820
128.3
F 30°
4000
80
DALI-2
ø368x421
ET94
New
14060
128.3
F 30°
3000
80
DALI-2
ø368x421
ET90
New
13528
128.3
F 30°
2700
80
DALI-2
ø368x421
ET86
New
11970
128.3
F 30°
2200
80
DALI-2
ø368x421
ET83
New
14430
128.3
WF 44°
4000
80
DALI-2
ø368x421
ET95
New
13690
128.3
WF 44°
3000
80
DALI-2
ø368x421
ET91
New
13172
128.3
WF 44°
2700
80
DALI-2
ø368x421
ET87
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
9675
121.6
SS 4.3°
4000
80
DALI-2
ø368x421
EU06
New
8812.5
121.6
SS 4.3°
3000
80
DALI-2
ø368x421
EU02
New
8362.5
121.6
SS 4.3°
2700
80
DALI-2
ø368x421
ET98
New
6600
121.6
SS 4.3°
2200
80
DALI-2
ø368x421
ET96
New
18172
161.8
S 16°
4000
80
DALI-2
ø368x421
EU07
New
17209.5
161.8
S 16°
3000
80
DALI-2
ø368x421
EU03
New
16555
161.8
S 16°
2700
80
DALI-2
ø368x421
ET99
New
17936
161.8
F 30°
4000
80
DALI-2
ø368x421
EU08
New
16986
161.8
F 30°
3000
80
DALI-2
ø368x421
EU04
New
16340
161.8
F 30°
2700
80
DALI-2
ø368x421
EU00
New
14478
161.8
F 30°
2200
80
DALI-2
ø368x421
ET97
New
17464
161.8
WF 44°
4000
80
DALI-2
ø368x421
EU09
New
16539
161.8
WF 44°
3000
80
DALI-2
ø368x421
EU05
New
15910
161.8
WF 44°
2700
80
DALI-2
ø368x421
EU01
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
Agorà ø516mm compact
36 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
11325
137.1
SS 4.3°
4000
80
DALI-2
ø516x571
EU62
New
10275
137.1
SS 4.3°
3000
80
DALI-2
ø516x571
EU58
New
9787.5
137.1
SS 4.3°
2700
80
DALI-2
ø516x571
EU54
New
7725
137.1
SS 4.3°
2200
80
DALI-2
ø516x571
EU52
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
13762.5
176.4
SS 4.3°
4000
80
DALI-2
ø516x571
EU76
New
12487.5
176.4
SS 4.3°
3000
80
DALI-2
ø516x571
EU72
New
11887.5
176.4
SS 4.3°
2700
80
DALI-2
ø516x571
EU68
New
9375
176.4
SS 4.3°
2200
80
DALI-2
ø516x571
EU66
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
13650
158.8
SS 4.3°
4000
80
DALI-2
ø516x571
EV18
New
12412.5
158.8
SS 4.3°
3000
80
DALI-2
ø516x571
EV14
New
11775
158.8
SS 4.3°
2700
80
DALI-2
ø516x571
EV10
New
9300
158.8
SS 4.3°
2200
80
DALI-2
ø516x571
EV08
New
26449.5
222.1
S 16°
4000
80
DALI-2
ø516x571
EV19
New
25063.5
222.1
S 16°
3000
80
DALI-2
ø516x571
EV15
New
24101
222.1
S 16°
2700
80
DALI-2
ø516x571
EV11
New
26106
222.1
F 28°
4000
80
DALI-2
ø516x571
EV20
New
24738
222.1
F 28°
3000
80
DALI-2
ø516x571
EV16
New
23788
222.1
F 28°
2700
80
DALI-2
ø516x571
EV12
New
21052
222.1
F 28°
2200
80
DALI-2
ø516x571
EV09
New
25419
222.1
WF 44°
4000
80
DALI-2
ø516x571
EV21
New
24087
222.1
WF 44°
3000
80
DALI-2
ø516x571
EV17
New
23162
222.1
WF 44°
2700
80
DALI-2
ø516x571
EV13
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
16987.5
207.8
SS 4.3°
4000
80
DALI-2
ø516x571
EV32
New
15450
207.8
SS 4.3°
3000
80
DALI-2
ø516x571
EV28
New
14662.5
207.8
SS 4.3°
2700
80
DALI-2
ø516x571
EV24
New
11587.5
207.8
SS 4.3°
2200
80
DALI-2
ø516x571
EV22
New
30415
267.3
S 16°
4000
80
DALI-2
ø516x571
EV33
New
28798
267.3
S 16°
3000
80
DALI-2
ø516x571
EV29
New
27758.5
267.3
S 16°
2700
80
DALI-2
ø516x571
EV25
New
30020
267.3
F 28°
4000
80
DALI-2
ø516x571
EV34
New
28424
267.3
F 28°
3000
80
DALI-2
ø516x571
EV30
New
27398
267.3
F 28°
2700
80
DALI-2
ø516x571
EV26
New
24244
267.3
F 28°
2200
80
DALI-2
ø516x571
EV23
New
29230
267.3
WF 44°
4000
80
DALI-2
ø516x571
EV35
New
27676
267.3
WF 44°
3000
80
DALI-2
ø516x571
EV31
New
26677
267.3
WF 44°
2700
80
DALI-2
ø516x571
EV27
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
Agorà ø516mm compact COB
24 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
29142.75
252.3
F 36°
4000
80
DALI-2
ø516x571
EV87
New
28444.5
252.3
F 36°
3000
80
DALI-2
ø516x571
EV84
New
27195
252.3
F 36°
2700
80
DALI-2
ø516x571
EV81
New
26790.75
252.3
F 36°
2200
65
DALI-2
ø516x571
EV78
New
29142.75
252.3
WF 46°
4000
80
DALI-2
ø516x571
EV88
New
28444.5
252.3
WF 46°
3000
80
DALI-2
ø516x571
EV85
New
27195
252.3
WF 46°
2700
80
DALI-2
ø516x571
EV82
New
26790.75
252.3
WF 46°
2200
65
DALI-2
ø516x571
EV79
New
34099
252.3
VWF 78°
4000
80
DALI-2
ø516x571
EV89
New
33282
252.3
VWF 78°
3000
80
DALI-2
ø516x571
EV86
New
31820
252.3
VWF 78°
2700
80
DALI-2
ø516x571
EV83
New
31347
252.3
VWF 78°
2200
65
DALI-2
ø516x571
EV80
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
C.o.B.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
30061.5
298.9
F 36°
2200
65
DALI-2
ø516x571
EV90
New
34104
306.9
F 36°
4000
80
DALI-2
ø516x571
EV99
New
33332.25
306.9
F 36°
3000
80
DALI-2
ø516x571
EV96
New
31862.25
306.9
F 36°
2700
80
DALI-2
ø516x571
EV93
New
30061.5
298.9
WF 46°
2200
65
DALI-2
ø516x571
EV91
New
34104
306.9
WF 46°
4000
80
DALI-2
ø516x571
EW00
New
33332.25
306.9
WF 46°
3000
80
DALI-2
ø516x571
EV97
New
31862.25
306.9
WF 46°
2700
80
DALI-2
ø516x571
EV94
New
35174
298.9
VWF 78°
2200
65
DALI-2
ø516x571
EV92
New
39904
306.9
VWF 78°
4000
80
DALI-2
ø516x571
EW01
New
39001
306.9
VWF 78°
3000
80
DALI-2
ø516x571
EV98
New
37281
306.9
VWF 78°
2700
80
DALI-2
ø516x571
EV95
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
Multi Agorà pole mounted
152 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
4425
53.5
SS 4.3°
4000
80
DALI-2
ø313x363
ET07
New
4050
53.5
SS 4.3°
3000
80
DALI-2
ø313x363
ET02
New
3825
53.5
SS 4.3°
2700
80
DALI-2
ø313x363
ES97
New
3037.5
53.5
SS 4.3°
2200
80
DALI-2
ø313x363
ES94
New
7469
63.3
S 16°
4000
80
DALI-2
ø313x363
ET08
New
7084
63.3
S 16°
3000
80
DALI-2
ø313x363
ET03
New
6814.5
63.3
S 16°
2700
80
DALI-2
ø313x363
ES98
New
7372
63.3
F 30°
4000
80
DALI-2
ø313x363
ET09
New
6992
63.3
F 30°
3000
80
DALI-2
ø313x363
ET04
New
6726
63.3
F 30°
2700
80
DALI-2
ø313x363
ES99
New
5928
63.3
F 30°
2200
80
DALI-2
ø313x363
ES95
New
7178
63.3
WF 50°
4000
80
DALI-2
ø313x363
ET10
New
6808
63.3
WF 50°
3000
80
DALI-2
ø313x363
ET05
New
6549
63.3
WF 50°
2700
80
DALI-2
ø313x363
ET00
New
6014
63.3
WW
4000
80
DALI-2
ø313x363
ET11
New
5704
63.3
WW
3000
80
DALI-2
ø313x363
ET06
New
5487
63.3
WW
2700
80
DALI-2
ø313x363
ET01
New
4836
63.3
WW
2200
80
DALI-2
ø313x363
ES96
Complete with power supply.
These codes can be used at a maximum environment temperature of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
5550
71.1
SS 4.3°
4000
80
DALI-2
ø313x363
ET25
New
5062.5
71.1
SS 4.3°
3000
80
DALI-2
ø313x363
ET20
New
4800
71.1
SS 4.3°
2700
80
DALI-2
ø313x363
ET15
New
3787.5
71.1
SS 4.3°
2200
80
DALI-2
ø313x363
ET12
New
9625
86.9
S 16°
4000
80
DALI-2
ø313x363
ET26
New
9124.5
86.9
S 16°
3000
80
DALI-2
ø313x363
ET21
New
8778
86.9
S 16°
2700
80
DALI-2
ø313x363
ET16
New
9500
86.9
F 30°
4000
80
DALI-2
ø313x363
ET27
New
9006
86.9
F 30°
3000
80
DALI-2
ø313x363
ET22
New
8664
86.9
F 30°
2700
80
DALI-2
ø313x363
ET17
New
7676
86.9
F 30°
2200
80
DALI-2
ø313x363
ET13
New
9250
86.9
WF 50°
4000
80
DALI-2
ø313x363
ET28
New
8769
86.9
WF 50°
3000
80
DALI-2
ø313x363
ET23
New
8436
86.9
WF 50°
2700
80
DALI-2
ø313x363
ET18
New
7750
86.9
WW
4000
80
DALI-2
ø313x363
ET29
New
7493.94
86.9
WW
3000
80
DALI-2
ø313x363
ET24
New
7068
86.9
WW
2700
80
DALI-2
ø313x363
ET19
New
6262
86.9
WW
2200
80
DALI-2
ø313x363
ET14
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
7687.5
89.3
SS 4.3°
4000
80
DALI-2
ø368x421
ET92
New
6975
89.3
SS 4.3°
3000
80
DALI-2
ø368x421
ET88
New
6637.5
89.3
SS 4.3°
2700
80
DALI-2
ø368x421
ET84
New
5212.5
89.3
SS 4.3°
2200
80
DALI-2
ø368x421
ET82
New
15015
128.3
S 16°
4000
80
DALI-2
ø368x421
ET93
New
14245
128.3
S 16°
3000
80
DALI-2
ø368x421
ET89
New
13706
128.3
S 16°
2700
80
DALI-2
ø368x421
ET85
New
14820
128.3
F 30°
4000
80
DALI-2
ø368x421
ET94
New
14060
128.3
F 30°
3000
80
DALI-2
ø368x421
ET90
New
13528
128.3
F 30°
2700
80
DALI-2
ø368x421
ET86
New
11970
128.3
F 30°
2200
80
DALI-2
ø368x421
ET83
New
14430
128.3
WF 44°
4000
80
DALI-2
ø368x421
ET95
New
13690
128.3
WF 44°
3000
80
DALI-2
ø368x421
ET91
New
13172
128.3
WF 44°
2700
80
DALI-2
ø368x421
ET87
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
11325
137.1
SS 4.3°
4000
80
DALI-2
ø516x571
EU62
New
10275
137.1
SS 4.3°
3000
80
DALI-2
ø516x571
EU58
New
9787.5
137.1
SS 4.3°
2700
80
DALI-2
ø516x571
EU54
New
7725
137.1
SS 4.3°
2200
80
DALI-2
ø516x571
EU52
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
13762.5
176.4
SS 4.3°
4000
80
DALI-2
ø516x571
EU76
New
12487.5
176.4
SS 4.3°
3000
80
DALI-2
ø516x571
EU72
New
11887.5
176.4
SS 4.3°
2700
80
DALI-2
ø516x571
EU68
New
9375
176.4
SS 4.3°
2200
80
DALI-2
ø516x571
EU66
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
29142.75
252.3
F 36°
4000
80
DALI-2
ø516x571
EV87
New
28444.5
252.3
F 36°
3000
80
DALI-2
ø516x571
EV84
New
27195
252.3
F 36°
2700
80
DALI-2
ø516x571
EV81
New
26790.75
252.3
F 36°
2200
65
DALI-2
ø516x571
EV78
New
29142.75
252.3
WF 46°
4000
80
DALI-2
ø516x571
EV88
New
28444.5
252.3
WF 46°
3000
80
DALI-2
ø516x571
EV85
New
27195
252.3
WF 46°
2700
80
DALI-2
ø516x571
EV82
New
26790.75
252.3
WF 46°
2200
65
DALI-2
ø516x571
EV79
New
34099
252.3
VWF 78°
4000
80
DALI-2
ø516x571
EV89
New
33282
252.3
VWF 78°
3000
80
DALI-2
ø516x571
EV86
New
31820
252.3
VWF 78°
2700
80
DALI-2
ø516x571
EV83
New
31347
252.3
VWF 78°
2200
65
DALI-2
ø516x571
EV80
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
9675
121.6
SS 4.3°
4000
80
DALI-2
ø368x421
EU06
New
8812.5
121.6
SS 4.3°
3000
80
DALI-2
ø368x421
EU02
New
8362.5
121.6
SS 4.3°
2700
80
DALI-2
ø368x421
ET98
New
6600
121.6
SS 4.3°
2200
80
DALI-2
ø368x421
ET96
New
18172
161.8
S 16°
4000
80
DALI-2
ø368x421
EU07
New
17209.5
161.8
S 16°
3000
80
DALI-2
ø368x421
EU03
New
16555
161.8
S 16°
2700
80
DALI-2
ø368x421
ET99
New
17936
161.8
F 30°
4000
80
DALI-2
ø368x421
EU08
New
16986
161.8
F 30°
3000
80
DALI-2
ø368x421
EU04
New
16340
161.8
F 30°
2700
80
DALI-2
ø368x421
EU00
New
14478
161.8
F 30°
2200
80
DALI-2
ø368x421
ET97
New
17464
161.8
WF 44°
4000
80
DALI-2
ø368x421
EU09
New
16539
161.8
WF 44°
3000
80
DALI-2
ø368x421
EU05
New
15910
161.8
WF 44°
2700
80
DALI-2
ø368x421
EU01
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
C.o.B.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
30061.5
298.9
F 36°
2200
65
DALI-2
ø516x571
EV90
New
34104
306.9
F 36°
4000
80
DALI-2
ø516x571
EV99
New
33332.25
306.9
F 36°
3000
80
DALI-2
ø516x571
EV96
New
31862.25
306.9
F 36°
2700
80
DALI-2
ø516x571
EV93
New
30061.5
298.9
WF 46°
2200
65
DALI-2
ø516x571
EV91
New
34104
306.9
WF 46°
4000
80
DALI-2
ø516x571
EW00
New
33332.25
306.9
WF 46°
3000
80
DALI-2
ø516x571
EV97
New
31862.25
306.9
WF 46°
2700
80
DALI-2
ø516x571
EV94
New
35174
298.9
VWF 78°
2200
65
DALI-2
ø516x571
EV92
New
39904
306.9
VWF 78°
4000
80
DALI-2
ø516x571
EW01
New
39001
306.9
VWF 78°
3000
80
DALI-2
ø516x571
EV98
New
37281
306.9
VWF 78°
2700
80
DALI-2
ø516x571
EV95
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
5967.5
50.8
S 16°
4000
80
DALI-2
ø313x363
N466
New
5659.5
50.8
S 16°
3000
80
DALI-2
ø313x363
N462
New
5467
50.8
S 16°
2700
80
DALI-2
ø313x363
N458
New
5890
50.8
F 30°
4000
80
DALI-2
ø313x363
N467
New
5586
50.8
F 30°
3000
80
DALI-2
ø313x363
N463
New
5396
50.8
F 30°
2700
80
DALI-2
ø313x363
N459
New
4750
50.8
F 30°
2200
80
DALI-2
ø313x363
N456
New
5735
50.8
WF 50°
4000
80
DALI-2
ø313x363
N468
New
5439
50.8
WF 50°
3000
80
DALI-2
ø313x363
N464
New
5254
50.8
WF 50°
2700
80
DALI-2
ø313x363
N460
New
4805
50.8
WW
4000
80
DALI-2
ø313x363
N469
New
4557
50.8
WW
3000
80
DALI-2
ø313x363
N465
New
4402
50.8
WW
2700
80
DALI-2
ø313x363
N461
New
3875
50.8
WW
2200
80
DALI-2
ø313x363
N457
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
13650
158.8
SS 4.3°
4000
80
DALI-2
ø516x571
EV18
New
12412.5
158.8
SS 4.3°
3000
80
DALI-2
ø516x571
EV14
New
11775
158.8
SS 4.3°
2700
80
DALI-2
ø516x571
EV10
New
9300
158.8
SS 4.3°
2200
80
DALI-2
ø516x571
EV08
New
26449.5
222.1
S 16°
4000
80
DALI-2
ø516x571
EV19
New
25063.5
222.1
S 16°
3000
80
DALI-2
ø516x571
EV15
New
24101
222.1
S 16°
2700
80
DALI-2
ø516x571
EV11
New
26106
222.1
F 28°
4000
80
DALI-2
ø516x571
EV20
New
24738
222.1
F 28°
3000
80
DALI-2
ø516x571
EV16
New
23788
222.1
F 28°
2700
80
DALI-2
ø516x571
EV12
New
21052
222.1
F 28°
2200
80
DALI-2
ø516x571
EV09
New
25419
222.1
WF 44°
4000
80
DALI-2
ø516x571
EV21
New
24087
222.1
WF 44°
3000
80
DALI-2
ø516x571
EV17
New
23162
222.1
WF 44°
2700
80
DALI-2
ø516x571
EV13
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
8008
71.7
S 16°
4000
80
DALI-2
ø313x363
N480
New
7584.5
71.7
S 16°
3000
80
DALI-2
ø313x363
N476
New
7315
71.7
S 16°
2700
80
DALI-2
ø313x363
N472
New
7904
71.7
F 30°
4000
80
DALI-2
ø313x363
N481
New
7486
71.7
F 30°
3000
80
DALI-2
ø313x363
N477
New
7220
71.7
F 30°
2700
80
DALI-2
ø313x363
N473
New
6384
71.7
F 30°
2200
80
DALI-2
ø313x363
N470
New
7696
71.7
WF 50°
4000
80
DALI-2
ø313x363
N482
New
7289
71.7
WF 50°
3000
80
DALI-2
ø313x363
N478
New
7030
71.7
WF 50°
2700
80
DALI-2
ø313x363
N474
New
6448
71.7
WW
4000
80
DALI-2
ø313x363
N483
New
6107
71.7
WW
3000
80
DALI-2
ø313x363
N479
New
5890
71.7
WW
2700
80
DALI-2
ø313x363
N475
New
5208
71.7
WW
2200
80
DALI-2
ø313x363
N471
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
16987.5
207.8
SS 4.3°
4000
80
DALI-2
ø516x571
EV32
New
15450
207.8
SS 4.3°
3000
80
DALI-2
ø516x571
EV28
New
14662.5
207.8
SS 4.3°
2700
80
DALI-2
ø516x571
EV24
New
11587.5
207.8
SS 4.3°
2200
80
DALI-2
ø516x571
EV22
New
30415
267.3
S 16°
4000
80
DALI-2
ø516x571
EV33
New
28798
267.3
S 16°
3000
80
DALI-2
ø516x571
EV29
New
27758.5
267.3
S 16°
2700
80
DALI-2
ø516x571
EV25
New
30020
267.3
F 28°
4000
80
DALI-2
ø516x571
EV34
New
28424
267.3
F 28°
3000
80
DALI-2
ø516x571
EV30
New
27398
267.3
F 28°
2700
80
DALI-2
ø516x571
EV26
New
24244
267.3
F 28°
2200
80
DALI-2
ø516x571
EV23
New
29230
267.3
WF 44°
4000
80
DALI-2
ø516x571
EV35
New
27676
267.3
WF 44°
3000
80
DALI-2
ø516x571
EV31
New
26677
267.3
WF 44°
2700
80
DALI-2
ø516x571
EV27
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
Multi Agorà minimal and connected pole
152 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
4425
53.5
SS 4.3°
4000
80
DALI-2
ø313x363
ET07
New
4050
53.5
SS 4.3°
3000
80
DALI-2
ø313x363
ET02
New
3825
53.5
SS 4.3°
2700
80
DALI-2
ø313x363
ES97
New
3037.5
53.5
SS 4.3°
2200
80
DALI-2
ø313x363
ES94
New
7469
63.3
S 16°
4000
80
DALI-2
ø313x363
ET08
New
7084
63.3
S 16°
3000
80
DALI-2
ø313x363
ET03
New
6814.5
63.3
S 16°
2700
80
DALI-2
ø313x363
ES98
New
7372
63.3
F 30°
4000
80
DALI-2
ø313x363
ET09
New
6992
63.3
F 30°
3000
80
DALI-2
ø313x363
ET04
New
6726
63.3
F 30°
2700
80
DALI-2
ø313x363
ES99
New
5928
63.3
F 30°
2200
80
DALI-2
ø313x363
ES95
New
7178
63.3
WF 50°
4000
80
DALI-2
ø313x363
ET10
New
6808
63.3
WF 50°
3000
80
DALI-2
ø313x363
ET05
New
6549
63.3
WF 50°
2700
80
DALI-2
ø313x363
ET00
New
6014
63.3
WW
4000
80
DALI-2
ø313x363
ET11
New
5704
63.3
WW
3000
80
DALI-2
ø313x363
ET06
New
5487
63.3
WW
2700
80
DALI-2
ø313x363
ET01
New
4836
63.3
WW
2200
80
DALI-2
ø313x363
ES96
Complete with power supply.
These codes can be used at a maximum environment temperature of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
5550
71.1
SS 4.3°
4000
80
DALI-2
ø313x363
ET25
New
5062.5
71.1
SS 4.3°
3000
80
DALI-2
ø313x363
ET20
New
4800
71.1
SS 4.3°
2700
80
DALI-2
ø313x363
ET15
New
3787.5
71.1
SS 4.3°
2200
80
DALI-2
ø313x363
ET12
New
9625
86.9
S 16°
4000
80
DALI-2
ø313x363
ET26
New
9124.5
86.9
S 16°
3000
80
DALI-2
ø313x363
ET21
New
8778
86.9
S 16°
2700
80
DALI-2
ø313x363
ET16
New
9500
86.9
F 30°
4000
80
DALI-2
ø313x363
ET27
New
9006
86.9
F 30°
3000
80
DALI-2
ø313x363
ET22
New
8664
86.9
F 30°
2700
80
DALI-2
ø313x363
ET17
New
7676
86.9
F 30°
2200
80
DALI-2
ø313x363
ET13
New
9250
86.9
WF 50°
4000
80
DALI-2
ø313x363
ET28
New
8769
86.9
WF 50°
3000
80
DALI-2
ø313x363
ET23
New
8436
86.9
WF 50°
2700
80
DALI-2
ø313x363
ET18
New
7750
86.9
WW
4000
80
DALI-2
ø313x363
ET29
New
7493.94
86.9
WW
3000
80
DALI-2
ø313x363
ET24
New
7068
86.9
WW
2700
80
DALI-2
ø313x363
ET19
New
6262
86.9
WW
2200
80
DALI-2
ø313x363
ET14
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
7687.5
89.3
SS 4.3°
4000
80
DALI-2
ø368x421
ET92
New
6975
89.3
SS 4.3°
3000
80
DALI-2
ø368x421
ET88
New
6637.5
89.3
SS 4.3°
2700
80
DALI-2
ø368x421
ET84
New
5212.5
89.3
SS 4.3°
2200
80
DALI-2
ø368x421
ET82
New
15015
128.3
S 16°
4000
80
DALI-2
ø368x421
ET93
New
14245
128.3
S 16°
3000
80
DALI-2
ø368x421
ET89
New
13706
128.3
S 16°
2700
80
DALI-2
ø368x421
ET85
New
14820
128.3
F 30°
4000
80
DALI-2
ø368x421
ET94
New
14060
128.3
F 30°
3000
80
DALI-2
ø368x421
ET90
New
13528
128.3
F 30°
2700
80
DALI-2
ø368x421
ET86
New
11970
128.3
F 30°
2200
80
DALI-2
ø368x421
ET83
New
14430
128.3
WF 44°
4000
80
DALI-2
ø368x421
ET95
New
13690
128.3
WF 44°
3000
80
DALI-2
ø368x421
ET91
New
13172
128.3
WF 44°
2700
80
DALI-2
ø368x421
ET87
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
11325
137.1
SS 4.3°
4000
80
DALI-2
ø516x571
EU62
New
10275
137.1
SS 4.3°
3000
80
DALI-2
ø516x571
EU58
New
9787.5
137.1
SS 4.3°
2700
80
DALI-2
ø516x571
EU54
New
7725
137.1
SS 4.3°
2200
80
DALI-2
ø516x571
EU52
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
13762.5
176.4
SS 4.3°
4000
80
DALI-2
ø516x571
EU76
New
12487.5
176.4
SS 4.3°
3000
80
DALI-2
ø516x571
EU72
New
11887.5
176.4
SS 4.3°
2700
80
DALI-2
ø516x571
EU68
New
9375
176.4
SS 4.3°
2200
80
DALI-2
ø516x571
EU66
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
29142.75
252.3
F 36°
4000
80
DALI-2
ø516x571
EV87
New
28444.5
252.3
F 36°
3000
80
DALI-2
ø516x571
EV84
New
27195
252.3
F 36°
2700
80
DALI-2
ø516x571
EV81
New
26790.75
252.3
F 36°
2200
65
DALI-2
ø516x571
EV78
New
29142.75
252.3
WF 46°
4000
80
DALI-2
ø516x571
EV88
New
28444.5
252.3
WF 46°
3000
80
DALI-2
ø516x571
EV85
New
27195
252.3
WF 46°
2700
80
DALI-2
ø516x571
EV82
New
26790.75
252.3
WF 46°
2200
65
DALI-2
ø516x571
EV79
New
34099
252.3
VWF 78°
4000
80
DALI-2
ø516x571
EV89
New
33282
252.3
VWF 78°
3000
80
DALI-2
ø516x571
EV86
New
31820
252.3
VWF 78°
2700
80
DALI-2
ø516x571
EV83
New
31347
252.3
VWF 78°
2200
65
DALI-2
ø516x571
EV80
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
9675
121.6
SS 4.3°
4000
80
DALI-2
ø368x421
EU06
New
8812.5
121.6
SS 4.3°
3000
80
DALI-2
ø368x421
EU02
New
8362.5
121.6
SS 4.3°
2700
80
DALI-2
ø368x421
ET98
New
6600
121.6
SS 4.3°
2200
80
DALI-2
ø368x421
ET96
New
18172
161.8
S 16°
4000
80
DALI-2
ø368x421
EU07
New
17209.5
161.8
S 16°
3000
80
DALI-2
ø368x421
EU03
New
16555
161.8
S 16°
2700
80
DALI-2
ø368x421
ET99
New
17936
161.8
F 30°
4000
80
DALI-2
ø368x421
EU08
New
16986
161.8
F 30°
3000
80
DALI-2
ø368x421
EU04
New
16340
161.8
F 30°
2700
80
DALI-2
ø368x421
EU00
New
14478
161.8
F 30°
2200
80
DALI-2
ø368x421
ET97
New
17464
161.8
WF 44°
4000
80
DALI-2
ø368x421
EU09
New
16539
161.8
WF 44°
3000
80
DALI-2
ø368x421
EU05
New
15910
161.8
WF 44°
2700
80
DALI-2
ø368x421
EU01
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
C.o.B.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
30061.5
298.9
F 36°
2200
65
DALI-2
ø516x571
EV90
New
34104
306.9
F 36°
4000
80
DALI-2
ø516x571
EV99
New
33332.25
306.9
F 36°
3000
80
DALI-2
ø516x571
EV96
New
31862.25
306.9
F 36°
2700
80
DALI-2
ø516x571
EV93
New
30061.5
298.9
WF 46°
2200
65
DALI-2
ø516x571
EV91
New
34104
306.9
WF 46°
4000
80
DALI-2
ø516x571
EW00
New
33332.25
306.9
WF 46°
3000
80
DALI-2
ø516x571
EV97
New
31862.25
306.9
WF 46°
2700
80
DALI-2
ø516x571
EV94
New
35174
298.9
VWF 78°
2200
65
DALI-2
ø516x571
EV92
New
39904
306.9
VWF 78°
4000
80
DALI-2
ø516x571
EW01
New
39001
306.9
VWF 78°
3000
80
DALI-2
ø516x571
EV98
New
37281
306.9
VWF 78°
2700
80
DALI-2
ø516x571
EV95
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
5967.5
50.8
S 16°
4000
80
DALI-2
ø313x363
N466
New
5659.5
50.8
S 16°
3000
80
DALI-2
ø313x363
N462
New
5467
50.8
S 16°
2700
80
DALI-2
ø313x363
N458
New
5890
50.8
F 30°
4000
80
DALI-2
ø313x363
N467
New
5586
50.8
F 30°
3000
80
DALI-2
ø313x363
N463
New
5396
50.8
F 30°
2700
80
DALI-2
ø313x363
N459
New
4750
50.8
F 30°
2200
80
DALI-2
ø313x363
N456
New
5735
50.8
WF 50°
4000
80
DALI-2
ø313x363
N468
New
5439
50.8
WF 50°
3000
80
DALI-2
ø313x363
N464
New
5254
50.8
WF 50°
2700
80
DALI-2
ø313x363
N460
New
4805
50.8
WW
4000
80
DALI-2
ø313x363
N469
New
4557
50.8
WW
3000
80
DALI-2
ø313x363
N465
New
4402
50.8
WW
2700
80
DALI-2
ø313x363
N461
New
3875
50.8
WW
2200
80
DALI-2
ø313x363
N457
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
13650
158.8
SS 4.3°
4000
80
DALI-2
ø516x571
EV18
New
12412.5
158.8
SS 4.3°
3000
80
DALI-2
ø516x571
EV14
New
11775
158.8
SS 4.3°
2700
80
DALI-2
ø516x571
EV10
New
9300
158.8
SS 4.3°
2200
80
DALI-2
ø516x571
EV08
New
26449.5
222.1
S 16°
4000
80
DALI-2
ø516x571
EV19
New
25063.5
222.1
S 16°
3000
80
DALI-2
ø516x571
EV15
New
24101
222.1
S 16°
2700
80
DALI-2
ø516x571
EV11
New
26106
222.1
F 28°
4000
80
DALI-2
ø516x571
EV20
New
24738
222.1
F 28°
3000
80
DALI-2
ø516x571
EV16
New
23788
222.1
F 28°
2700
80
DALI-2
ø516x571
EV12
New
21052
222.1
F 28°
2200
80
DALI-2
ø516x571
EV09
New
25419
222.1
WF 44°
4000
80
DALI-2
ø516x571
EV21
New
24087
222.1
WF 44°
3000
80
DALI-2
ø516x571
EV17
New
23162
222.1
WF 44°
2700
80
DALI-2
ø516x571
EV13
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
8008
71.7
S 16°
4000
80
DALI-2
ø313x363
N480
New
7584.5
71.7
S 16°
3000
80
DALI-2
ø313x363
N476
New
7315
71.7
S 16°
2700
80
DALI-2
ø313x363
N472
New
7904
71.7
F 30°
4000
80
DALI-2
ø313x363
N481
New
7486
71.7
F 30°
3000
80
DALI-2
ø313x363
N477
New
7220
71.7
F 30°
2700
80
DALI-2
ø313x363
N473
New
6384
71.7
F 30°
2200
80
DALI-2
ø313x363
N470
New
7696
71.7
WF 50°
4000
80
DALI-2
ø313x363
N482
New
7289
71.7
WF 50°
3000
80
DALI-2
ø313x363
N478
New
7030
71.7
WF 50°
2700
80
DALI-2
ø313x363
N474
New
6448
71.7
WW
4000
80
DALI-2
ø313x363
N483
New
6107
71.7
WW
3000
80
DALI-2
ø313x363
N479
New
5890
71.7
WW
2700
80
DALI-2
ø313x363
N475
New
5208
71.7
WW
2200
80
DALI-2
ø313x363
N471
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
16987.5
207.8
SS 4.3°
4000
80
DALI-2
ø516x571
EV32
New
15450
207.8
SS 4.3°
3000
80
DALI-2
ø516x571
EV28
New
14662.5
207.8
SS 4.3°
2700
80
DALI-2
ø516x571
EV24
New
11587.5
207.8
SS 4.3°
2200
80
DALI-2
ø516x571
EV22
New
30415
267.3
S 16°
4000
80
DALI-2
ø516x571
EV33
New
28798
267.3
S 16°
3000
80
DALI-2
ø516x571
EV29
New
27758.5
267.3
S 16°
2700
80
DALI-2
ø516x571
EV25
New
30020
267.3
F 28°
4000
80
DALI-2
ø516x571
EV34
New
28424
267.3
F 28°
3000
80
DALI-2
ø516x571
EV30
New
27398
267.3
F 28°
2700
80
DALI-2
ø516x571
EV26
New
24244
267.3
F 28°
2200
80
DALI-2
ø516x571
EV23
New
29230
267.3
WF 44°
4000
80
DALI-2
ø516x571
EV35
New
27676
267.3
WF 44°
3000
80
DALI-2
ø516x571
EV31
New
26677
267.3
WF 44°
2700
80
DALI-2
ø516x571
EV27
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
Multi Agorà wall mounted
152 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
4425
53.5
SS 4.3°
4000
80
DALI-2
ø313x363
ET07
New
4050
53.5
SS 4.3°
3000
80
DALI-2
ø313x363
ET02
New
3825
53.5
SS 4.3°
2700
80
DALI-2
ø313x363
ES97
New
3037.5
53.5
SS 4.3°
2200
80
DALI-2
ø313x363
ES94
New
7469
63.3
S 16°
4000
80
DALI-2
ø313x363
ET08
New
7084
63.3
S 16°
3000
80
DALI-2
ø313x363
ET03
New
6814.5
63.3
S 16°
2700
80
DALI-2
ø313x363
ES98
New
7372
63.3
F 30°
4000
80
DALI-2
ø313x363
ET09
New
6992
63.3
F 30°
3000
80
DALI-2
ø313x363
ET04
New
6726
63.3
F 30°
2700
80
DALI-2
ø313x363
ES99
New
5928
63.3
F 30°
2200
80
DALI-2
ø313x363
ES95
New
7178
63.3
WF 50°
4000
80
DALI-2
ø313x363
ET10
New
6808
63.3
WF 50°
3000
80
DALI-2
ø313x363
ET05
New
6549
63.3
WF 50°
2700
80
DALI-2
ø313x363
ET00
New
6014
63.3
WW
4000
80
DALI-2
ø313x363
ET11
New
5704
63.3
WW
3000
80
DALI-2
ø313x363
ET06
New
5487
63.3
WW
2700
80
DALI-2
ø313x363
ET01
New
4836
63.3
WW
2200
80
DALI-2
ø313x363
ES96
Complete with power supply.
These codes can be used at a maximum environment temperature of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
5550
71.1
SS 4.3°
4000
80
DALI-2
ø313x363
ET25
New
5062.5
71.1
SS 4.3°
3000
80
DALI-2
ø313x363
ET20
New
4800
71.1
SS 4.3°
2700
80
DALI-2
ø313x363
ET15
New
3787.5
71.1
SS 4.3°
2200
80
DALI-2
ø313x363
ET12
New
9625
86.9
S 16°
4000
80
DALI-2
ø313x363
ET26
New
9124.5
86.9
S 16°
3000
80
DALI-2
ø313x363
ET21
New
8778
86.9
S 16°
2700
80
DALI-2
ø313x363
ET16
New
9500
86.9
F 30°
4000
80
DALI-2
ø313x363
ET27
New
9006
86.9
F 30°
3000
80
DALI-2
ø313x363
ET22
New
8664
86.9
F 30°
2700
80
DALI-2
ø313x363
ET17
New
7676
86.9
F 30°
2200
80
DALI-2
ø313x363
ET13
New
9250
86.9
WF 50°
4000
80
DALI-2
ø313x363
ET28
New
8769
86.9
WF 50°
3000
80
DALI-2
ø313x363
ET23
New
8436
86.9
WF 50°
2700
80
DALI-2
ø313x363
ET18
New
7750
86.9
WW
4000
80
DALI-2
ø313x363
ET29
New
7493.94
86.9
WW
3000
80
DALI-2
ø313x363
ET24
New
7068
86.9
WW
2700
80
DALI-2
ø313x363
ET19
New
6262
86.9
WW
2200
80
DALI-2
ø313x363
ET14
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
7687.5
89.3
SS 4.3°
4000
80
DALI-2
ø368x421
ET92
New
6975
89.3
SS 4.3°
3000
80
DALI-2
ø368x421
ET88
New
6637.5
89.3
SS 4.3°
2700
80
DALI-2
ø368x421
ET84
New
5212.5
89.3
SS 4.3°
2200
80
DALI-2
ø368x421
ET82
New
15015
128.3
S 16°
4000
80
DALI-2
ø368x421
ET93
New
14245
128.3
S 16°
3000
80
DALI-2
ø368x421
ET89
New
13706
128.3
S 16°
2700
80
DALI-2
ø368x421
ET85
New
14820
128.3
F 30°
4000
80
DALI-2
ø368x421
ET94
New
14060
128.3
F 30°
3000
80
DALI-2
ø368x421
ET90
New
13528
128.3
F 30°
2700
80
DALI-2
ø368x421
ET86
New
11970
128.3
F 30°
2200
80
DALI-2
ø368x421
ET83
New
14430
128.3
WF 44°
4000
80
DALI-2
ø368x421
ET95
New
13690
128.3
WF 44°
3000
80
DALI-2
ø368x421
ET91
New
13172
128.3
WF 44°
2700
80
DALI-2
ø368x421
ET87
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
11325
137.1
SS 4.3°
4000
80
DALI-2
ø516x571
EU62
New
10275
137.1
SS 4.3°
3000
80
DALI-2
ø516x571
EU58
New
9787.5
137.1
SS 4.3°
2700
80
DALI-2
ø516x571
EU54
New
7725
137.1
SS 4.3°
2200
80
DALI-2
ø516x571
EU52
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
13762.5
176.4
SS 4.3°
4000
80
DALI-2
ø516x571
EU76
New
12487.5
176.4
SS 4.3°
3000
80
DALI-2
ø516x571
EU72
New
11887.5
176.4
SS 4.3°
2700
80
DALI-2
ø516x571
EU68
New
9375
176.4
SS 4.3°
2200
80
DALI-2
ø516x571
EU66
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
29142.75
252.3
F 36°
4000
80
DALI-2
ø516x571
EV87
New
28444.5
252.3
F 36°
3000
80
DALI-2
ø516x571
EV84
New
27195
252.3
F 36°
2700
80
DALI-2
ø516x571
EV81
New
26790.75
252.3
F 36°
2200
65
DALI-2
ø516x571
EV78
New
29142.75
252.3
WF 46°
4000
80
DALI-2
ø516x571
EV88
New
28444.5
252.3
WF 46°
3000
80
DALI-2
ø516x571
EV85
New
27195
252.3
WF 46°
2700
80
DALI-2
ø516x571
EV82
New
26790.75
252.3
WF 46°
2200
65
DALI-2
ø516x571
EV79
New
34099
252.3
VWF 78°
4000
80
DALI-2
ø516x571
EV89
New
33282
252.3
VWF 78°
3000
80
DALI-2
ø516x571
EV86
New
31820
252.3
VWF 78°
2700
80
DALI-2
ø516x571
EV83
New
31347
252.3
VWF 78°
2200
65
DALI-2
ø516x571
EV80
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
9675
121.6
SS 4.3°
4000
80
DALI-2
ø368x421
EU06
New
8812.5
121.6
SS 4.3°
3000
80
DALI-2
ø368x421
EU02
New
8362.5
121.6
SS 4.3°
2700
80
DALI-2
ø368x421
ET98
New
6600
121.6
SS 4.3°
2200
80
DALI-2
ø368x421
ET96
New
18172
161.8
S 16°
4000
80
DALI-2
ø368x421
EU07
New
17209.5
161.8
S 16°
3000
80
DALI-2
ø368x421
EU03
New
16555
161.8
S 16°
2700
80
DALI-2
ø368x421
ET99
New
17936
161.8
F 30°
4000
80
DALI-2
ø368x421
EU08
New
16986
161.8
F 30°
3000
80
DALI-2
ø368x421
EU04
New
16340
161.8
F 30°
2700
80
DALI-2
ø368x421
EU00
New
14478
161.8
F 30°
2200
80
DALI-2
ø368x421
ET97
New
17464
161.8
WF 44°
4000
80
DALI-2
ø368x421
EU09
New
16539
161.8
WF 44°
3000
80
DALI-2
ø368x421
EU05
New
15910
161.8
WF 44°
2700
80
DALI-2
ø368x421
EU01
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
C.o.B.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
30061.5
298.9
F 36°
2200
65
DALI-2
ø516x571
EV90
New
34104
306.9
F 36°
4000
80
DALI-2
ø516x571
EV99
New
33332.25
306.9
F 36°
3000
80
DALI-2
ø516x571
EV96
New
31862.25
306.9
F 36°
2700
80
DALI-2
ø516x571
EV93
New
30061.5
298.9
WF 46°
2200
65
DALI-2
ø516x571
EV91
New
34104
306.9
WF 46°
4000
80
DALI-2
ø516x571
EW00
New
33332.25
306.9
WF 46°
3000
80
DALI-2
ø516x571
EV97
New
31862.25
306.9
WF 46°
2700
80
DALI-2
ø516x571
EV94
New
35174
298.9
VWF 78°
2200
65
DALI-2
ø516x571
EV92
New
39904
306.9
VWF 78°
4000
80
DALI-2
ø516x571
EW01
New
39001
306.9
VWF 78°
3000
80
DALI-2
ø516x571
EV98
New
37281
306.9
VWF 78°
2700
80
DALI-2
ø516x571
EV95
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
5967.5
50.8
S 16°
4000
80
DALI-2
ø313x363
N466
New
5659.5
50.8
S 16°
3000
80
DALI-2
ø313x363
N462
New
5467
50.8
S 16°
2700
80
DALI-2
ø313x363
N458
New
5890
50.8
F 30°
4000
80
DALI-2
ø313x363
N467
New
5586
50.8
F 30°
3000
80
DALI-2
ø313x363
N463
New
5396
50.8
F 30°
2700
80
DALI-2
ø313x363
N459
New
4750
50.8
F 30°
2200
80
DALI-2
ø313x363
N456
New
5735
50.8
WF 50°
4000
80
DALI-2
ø313x363
N468
New
5439
50.8
WF 50°
3000
80
DALI-2
ø313x363
N464
New
5254
50.8
WF 50°
2700
80
DALI-2
ø313x363
N460
New
4805
50.8
WW
4000
80
DALI-2
ø313x363
N469
New
4557
50.8
WW
3000
80
DALI-2
ø313x363
N465
New
4402
50.8
WW
2700
80
DALI-2
ø313x363
N461
New
3875
50.8
WW
2200
80
DALI-2
ø313x363
N457
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
13650
158.8
SS 4.3°
4000
80
DALI-2
ø516x571
EV18
New
12412.5
158.8
SS 4.3°
3000
80
DALI-2
ø516x571
EV14
New
11775
158.8
SS 4.3°
2700
80
DALI-2
ø516x571
EV10
New
9300
158.8
SS 4.3°
2200
80
DALI-2
ø516x571
EV08
New
26449.5
222.1
S 16°
4000
80
DALI-2
ø516x571
EV19
New
25063.5
222.1
S 16°
3000
80
DALI-2
ø516x571
EV15
New
24101
222.1
S 16°
2700
80
DALI-2
ø516x571
EV11
New
26106
222.1
F 28°
4000
80
DALI-2
ø516x571
EV20
New
24738
222.1
F 28°
3000
80
DALI-2
ø516x571
EV16
New
23788
222.1
F 28°
2700
80
DALI-2
ø516x571
EV12
New
21052
222.1
F 28°
2200
80
DALI-2
ø516x571
EV09
New
25419
222.1
WF 44°
4000
80
DALI-2
ø516x571
EV21
New
24087
222.1
WF 44°
3000
80
DALI-2
ø516x571
EV17
New
23162
222.1
WF 44°
2700
80
DALI-2
ø516x571
EV13
Complete with power supply.
These codes can be used at a maximum environment temperature
of 50°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
8008
71.7
S 16°
4000
80
DALI-2
ø313x363
N480
New
7584.5
71.7
S 16°
3000
80
DALI-2
ø313x363
N476
New
7315
71.7
S 16°
2700
80
DALI-2
ø313x363
N472
New
7904
71.7
F 30°
4000
80
DALI-2
ø313x363
N481
New
7486
71.7
F 30°
3000
80
DALI-2
ø313x363
N477
New
7220
71.7
F 30°
2700
80
DALI-2
ø313x363
N473
New
6384
71.7
F 30°
2200
80
DALI-2
ø313x363
N470
New
7696
71.7
WF 50°
4000
80
DALI-2
ø313x363
N482
New
7289
71.7
WF 50°
3000
80
DALI-2
ø313x363
N478
New
7030
71.7
WF 50°
2700
80
DALI-2
ø313x363
N474
New
6448
71.7
WW
4000
80
DALI-2
ø313x363
N483
New
6107
71.7
WW
3000
80
DALI-2
ø313x363
N479
New
5890
71.7
WW
2700
80
DALI-2
ø313x363
N475
New
5208
71.7
WW
2200
80
DALI-2
ø313x363
N471
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
16987.5
207.8
SS 4.3°
4000
80
DALI-2
ø516x571
EV32
New
15450
207.8
SS 4.3°
3000
80
DALI-2
ø516x571
EV28
New
14662.5
207.8
SS 4.3°
2700
80
DALI-2
ø516x571
EV24
New
11587.5
207.8
SS 4.3°
2200
80
DALI-2
ø516x571
EV22
New
30415
267.3
S 16°
4000
80
DALI-2
ø516x571
EV33
New
28798
267.3
S 16°
3000
80
DALI-2
ø516x571
EV29
New
27758.5
267.3
S 16°
2700
80
DALI-2
ø516x571
EV25
New
30020
267.3
F 28°
4000
80
DALI-2
ø516x571
EV34
New
28424
267.3
F 28°
3000
80
DALI-2
ø516x571
EV30
New
27398
267.3
F 28°
2700
80
DALI-2
ø516x571
EV26
New
24244
267.3
F 28°
2200
80
DALI-2
ø516x571
EV23
New
29230
267.3
WF 44°
4000
80
DALI-2
ø516x571
EV35
New
27676
267.3
WF 44°
3000
80
DALI-2
ø516x571
EV31
New
26677
267.3
WF 44°
2700
80
DALI-2
ø516x571
EV27
Complete with power supply.
These codes can be used at a maximum environment temperature
of 35°C.
Lingotto
See Overview
Lingotto without base
48 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3400
28.6
A60
4000
80
DALI-2
270x240
763A
New
3090
28.6
A60
2200
70
DALI-2
270x240
755A
New
3230
28.9
A60
3000
80
DALI-2
270x240
759A
New
4790
42
A60
4000
80
DALI-2
270x240
775A
New
4350
42
A60
2200
70
DALI-2
270x240
767A
New
4550
42.4
A60
3000
80
DALI-2
270x240
771A
New
3440
28.6
ST1
4000
80
DALI-2
270x240
761A
New
3130
28.6
ST1
2200
70
DALI-2
270x240
753A
New
3270
28.9
ST1
3000
80
DALI-2
270x240
757A
New
4850
42
ST1
4000
80
DALI-2
270x240
773A
New
4410
42
ST1
2200
70
DALI-2
270x240
765A
New
4610
42.4
ST1
3000
80
DALI-2
270x240
769A
New
3070
28.6
ST1.5
4000
80
DALI-2
270x240
762A
New
2790
28.6
ST1.5
2200
70
DALI-2
270x240
754A
New
2920
28.9
ST1.5
3000
80
DALI-2
270x240
758A
New
4330
42
ST1.5
4000
80
DALI-2
270x240
774A
New
3940
42
ST1.5
2200
70
DALI-2
270x240
766A
New
4120
42.4
ST1.5
3000
80
DALI-2
270x240
770A
New
3260
28.6
STCy0.5
4000
80
DALI-2
270x240
760A
New
2960
28.6
STCy0.5
2200
70
DALI-2
270x240
752A
New
3100
28.9
STCy0.5
3000
80
DALI-2
270x240
756A
New
4590
42
STCy0.5
4000
80
DALI-2
270x240
772A
New
4170
42
STCy0.5
2200
70
DALI-2
270x240
764A
New
4370
42.4
STCy0.5
3000
80
DALI-2
270x240
768A
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3670
28.6
A60
4000
80
DALI-2
270x240
787A
New
3340
28.6
A60
2200
70
DALI-2
270x240
779A
New
3490
28.9
A60
3000
80
DALI-2
270x240
783A
New
5180
42
A60
4000
80
DALI-2
270x240
799A
New
4710
42
A60
2200
70
DALI-2
270x240
791A
New
4930
42.4
A60
3000
80
DALI-2
270x240
795A
New
3810
28.6
ST1
4000
80
DALI-2
270x240
785A
New
3470
28.6
ST1
2200
70
DALI-2
270x240
777A
New
3630
28.9
ST1
3000
80
DALI-2
270x240
781A
New
5380
42
ST1
4000
80
DALI-2
270x240
797A
New
4890
42
ST1
2200
70
DALI-2
270x240
789A
New
5110
42.4
ST1
3000
80
DALI-2
270x240
793A
New
3490
28.6
ST1.5
4000
80
DALI-2
270x240
786A
New
3170
28.6
ST1.5
2200
70
DALI-2
270x240
778A
New
3320
28.9
ST1.5
3000
80
DALI-2
270x240
782A
New
4920
42
ST1.5
4000
80
DALI-2
270x240
798A
New
4470
42
ST1.5
2200
70
DALI-2
270x240
790A
New
4680
42.4
ST1.5
3000
80
DALI-2
270x240
794A
New
3670
28.6
STCy0.5
4000
80
DALI-2
270x240
784A
New
3340
28.6
STCy0.5
2200
70
DALI-2
270x240
776A
New
3490
28.9
STCy0.5
3000
80
DALI-2
270x240
780A
New
5180
42
STCy0.5
4000
80
DALI-2
270x240
796A
New
4710
42
STCy0.5
2200
70
DALI-2
270x240
788A
New
4930
42.4
STCy0.5
3000
80
DALI-2
270x240
792A
Lingotto with base
52 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3670
28.6
A60
4000
80
DALI-2
270x240
PY17
New
3340
28.6
A60
2200
70
DALI-2
270x240
PX85
New
3490
28.9
A60
3000
80
DALI-2
270x240
PX89
New
5180
42
A60
4000
80
DALI-2
270x240
PY29
New
4710
42
A60
2200
70
DALI-2
270x240
PY21
New
4930
42.4
A60
3000
80
DALI-2
270x240
PY25
New
3810
28.6
ST1
4000
80
DALI-2
270x240
PX91
New
3470
28.6
ST1
2200
70
DALI-2
270x240
PX83
New
3630
28.9
ST1
3000
80
DALI-2
270x240
PX87
New
5380
42
ST1
4000
80
DALI-2
270x240
PY27
New
4890
42
ST1
2200
70
DALI-2
270x240
PY19
New
5110
42.4
ST1
3000
80
DALI-2
270x240
PY23
New
3490
28.6
ST1.5
4000
80
DALI-2
270x240
PY16
New
3170
28.6
ST1.5
2200
70
DALI-2
270x240
PX84
New
3320
28.9
ST1.5
3000
80
DALI-2
270x240
PX88
New
4920
42
ST1.5
4000
80
DALI-2
270x240
PY28
New
4470
42
ST1.5
2200
70
DALI-2
270x240
PY20
New
4680
42.4
ST1.5
3000
80
DALI-2
270x240
PY24
New
3670
28.6
STCy0.5
4000
80
DALI-2
270x240
PX90
New
3340
28.6
STCy0.5
2200
70
DALI-2
270x240
PX82
New
3490
28.9
STCy0.5
3000
80
DALI-2
270x240
PX86
New
5180
42
STCy0.5
4000
80
DALI-2
270x240
PY26
New
4710
42
STCy0.5
2200
70
DALI-2
270x240
PY18
New
4930
42.4
STCy0.5
3000
80
DALI-2
270x240
PY22
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3400
28.6
A60
4000
80
DALI-2
270x240
PX69
New
3090
28.6
A60
2200
70
DALI-2
270x240
PX45
New
3230
28.9
A60
3000
80
DALI-2
270x240
PX49
New
4790
42
A60
4000
80
DALI-2
270x240
PX81
New
4350
42
A60
2200
70
DALI-2
270x240
PX73
New
4550
42.4
A60
3000
80
DALI-2
270x240
PX77
New
3440
28.6
ST1
4000
80
DALI-2
270x240
PX51
New
3130
28.6
ST1
2200
70
DALI-2
270x240
PX43
New
3270
28.9
ST1
3000
80
DALI-2
270x240
PX47
New
4850
42
ST1
4000
80
DALI-2
270x240
PX79
New
4410
42
ST1
2200
70
DALI-2
270x240
PX71
New
4610
42.4
ST1
3000
80
DALI-2
270x240
PX75
New
3070
28.6
ST1.5
4000
80
DALI-2
270x240
PX68
New
2790
28.6
ST1.5
2200
70
DALI-2
270x240
PX44
New
2920
28.9
ST1.5
3000
80
DALI-2
270x240
PX48
New
4330
42
ST1.5
4000
80
DALI-2
270x240
PX80
New
3940
42
ST1.5
2200
70
DALI-2
270x240
PX72
New
4120
42.4
ST1.5
3000
80
DALI-2
270x240
PX76
New
3260
28.6
STCy0.5
4000
80
DALI-2
270x240
PX50
New
2960
28.6
STCy0.5
2200
70
DALI-2
270x240
PX42
New
3100
28.9
STCy0.5
3000
80
DALI-2
270x240
PX46
New
4590
42
STCy0.5
4000
80
DALI-2
270x240
PX78
New
4170
42
STCy0.5
2200
70
DALI-2
270x240
PX70
New
4370
42.4
STCy0.5
3000
80
DALI-2
270x240
PX74
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
2623
19.8
GL
4000
80
DALI-2
270x240
PW81
New
2597.2
19.8
GL
3500
80
DALI-2
270x240
PW80
New
2562.8
19.8
GL
3000
80
DALI-2
270x240
PW79
New
2399.4
20.6
GL
2200
65
DALI-2
270x240
PW78
Multi Lingotto pole mounted
96 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3400
28.6
A60
4000
80
DALI-2
270x240
PX69
New
3090
28.6
A60
2200
70
DALI-2
270x240
PX45
New
3230
28.9
A60
3000
80
DALI-2
270x240
PX49
New
4790
42
A60
4000
80
DALI-2
270x240
PX81
New
4350
42
A60
2200
70
DALI-2
270x240
PX73
New
4550
42.4
A60
3000
80
DALI-2
270x240
PX77
New
3440
28.6
ST1
4000
80
DALI-2
270x240
PX51
New
3130
28.6
ST1
2200
70
DALI-2
270x240
PX43
New
3270
28.9
ST1
3000
80
DALI-2
270x240
PX47
New
4850
42
ST1
4000
80
DALI-2
270x240
PX79
New
4410
42
ST1
2200
70
DALI-2
270x240
PX71
New
4610
42.4
ST1
3000
80
DALI-2
270x240
PX75
New
3070
28.6
ST1.5
4000
80
DALI-2
270x240
PX68
New
2790
28.6
ST1.5
2200
70
DALI-2
270x240
PX44
New
2920
28.9
ST1.5
3000
80
DALI-2
270x240
PX48
New
4330
42
ST1.5
4000
80
DALI-2
270x240
PX80
New
3940
42
ST1.5
2200
70
DALI-2
270x240
PX72
New
4120
42.4
ST1.5
3000
80
DALI-2
270x240
PX76
New
3260
28.6
STCy0.5
4000
80
DALI-2
270x240
PX50
New
2960
28.6
STCy0.5
2200
70
DALI-2
270x240
PX42
New
3100
28.9
STCy0.5
3000
80
DALI-2
270x240
PX46
New
4590
42
STCy0.5
4000
80
DALI-2
270x240
PX78
New
4170
42
STCy0.5
2200
70
DALI-2
270x240
PX70
New
4370
42.4
STCy0.5
3000
80
DALI-2
270x240
PX74
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3670
28.6
A60
4000
80
DALI-2
270x240
PY17
New
3340
28.6
A60
2200
70
DALI-2
270x240
PX85
New
3490
28.9
A60
3000
80
DALI-2
270x240
PX89
New
5180
42
A60
4000
80
DALI-2
270x240
PY29
New
4710
42
A60
2200
70
DALI-2
270x240
PY21
New
4930
42.4
A60
3000
80
DALI-2
270x240
PY25
New
3810
28.6
ST1
4000
80
DALI-2
270x240
PX91
New
3470
28.6
ST1
2200
70
DALI-2
270x240
PX83
New
3630
28.9
ST1
3000
80
DALI-2
270x240
PX87
New
5380
42
ST1
4000
80
DALI-2
270x240
PY27
New
4890
42
ST1
2200
70
DALI-2
270x240
PY19
New
5110
42.4
ST1
3000
80
DALI-2
270x240
PY23
New
3490
28.6
ST1.5
4000
80
DALI-2
270x240
PY16
New
3170
28.6
ST1.5
2200
70
DALI-2
270x240
PX84
New
3320
28.9
ST1.5
3000
80
DALI-2
270x240
PX88
New
4920
42
ST1.5
4000
80
DALI-2
270x240
PY28
New
4470
42
ST1.5
2200
70
DALI-2
270x240
PY20
New
4680
42.4
ST1.5
3000
80
DALI-2
270x240
PY24
New
3670
28.6
STCy0.5
4000
80
DALI-2
270x240
PX90
New
3340
28.6
STCy0.5
2200
70
DALI-2
270x240
PX82
New
3490
28.9
STCy0.5
3000
80
DALI-2
270x240
PX86
New
5180
42
STCy0.5
4000
80
DALI-2
270x240
PY26
New
4710
42
STCy0.5
2200
70
DALI-2
270x240
PY18
New
4930
42.4
STCy0.5
3000
80
DALI-2
270x240
PY22
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3400
28.6
A60
4000
80
DALI-2
270x240
763A
New
3090
28.6
A60
2200
70
DALI-2
270x240
755A
New
3230
28.9
A60
3000
80
DALI-2
270x240
759A
New
4790
42
A60
4000
80
DALI-2
270x240
775A
New
4350
42
A60
2200
70
DALI-2
270x240
767A
New
4550
42.4
A60
3000
80
DALI-2
270x240
771A
New
3440
28.6
ST1
4000
80
DALI-2
270x240
761A
New
3130
28.6
ST1
2200
70
DALI-2
270x240
753A
New
3270
28.9
ST1
3000
80
DALI-2
270x240
757A
New
4850
42
ST1
4000
80
DALI-2
270x240
773A
New
4410
42
ST1
2200
70
DALI-2
270x240
765A
New
4610
42.4
ST1
3000
80
DALI-2
270x240
769A
New
3070
28.6
ST1.5
4000
80
DALI-2
270x240
762A
New
2790
28.6
ST1.5
2200
70
DALI-2
270x240
754A
New
2920
28.9
ST1.5
3000
80
DALI-2
270x240
758A
New
4330
42
ST1.5
4000
80
DALI-2
270x240
774A
New
3940
42
ST1.5
2200
70
DALI-2
270x240
766A
New
4120
42.4
ST1.5
3000
80
DALI-2
270x240
770A
New
3260
28.6
STCy0.5
4000
80
DALI-2
270x240
760A
New
2960
28.6
STCy0.5
2200
70
DALI-2
270x240
752A
New
3100
28.9
STCy0.5
3000
80
DALI-2
270x240
756A
New
4590
42
STCy0.5
4000
80
DALI-2
270x240
772A
New
4170
42
STCy0.5
2200
70
DALI-2
270x240
764A
New
4370
42.4
STCy0.5
3000
80
DALI-2
270x240
768A
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3670
28.6
A60
4000
80
DALI-2
270x240
787A
New
3340
28.6
A60
2200
70
DALI-2
270x240
779A
New
3490
28.9
A60
3000
80
DALI-2
270x240
783A
New
5180
42
A60
4000
80
DALI-2
270x240
799A
New
4710
42
A60
2200
70
DALI-2
270x240
791A
New
4930
42.4
A60
3000
80
DALI-2
270x240
795A
New
3810
28.6
ST1
4000
80
DALI-2
270x240
785A
New
3470
28.6
ST1
2200
70
DALI-2
270x240
777A
New
3630
28.9
ST1
3000
80
DALI-2
270x240
781A
New
5380
42
ST1
4000
80
DALI-2
270x240
797A
New
4890
42
ST1
2200
70
DALI-2
270x240
789A
New
5110
42.4
ST1
3000
80
DALI-2
270x240
793A
New
3490
28.6
ST1.5
4000
80
DALI-2
270x240
786A
New
3170
28.6
ST1.5
2200
70
DALI-2
270x240
778A
New
3320
28.9
ST1.5
3000
80
DALI-2
270x240
782A
New
4920
42
ST1.5
4000
80
DALI-2
270x240
798A
New
4470
42
ST1.5
2200
70
DALI-2
270x240
790A
New
4680
42.4
ST1.5
3000
80
DALI-2
270x240
794A
New
3670
28.6
STCy0.5
4000
80
DALI-2
270x240
784A
New
3340
28.6
STCy0.5
2200
70
DALI-2
270x240
776A
New
3490
28.9
STCy0.5
3000
80
DALI-2
270x240
780A
New
5180
42
STCy0.5
4000
80
DALI-2
270x240
796A
New
4710
42
STCy0.5
2200
70
DALI-2
270x240
788A
New
4930
42.4
STCy0.5
3000
80
DALI-2
270x240
792A
Multi Lingotto minimal and connected pole
48 code(s)
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3400
28.6
A60
4000
80
DALI-2
270x240
763A
New
3090
28.6
A60
2200
70
DALI-2
270x240
755A
New
3230
28.9
A60
3000
80
DALI-2
270x240
759A
New
4790
42
A60
4000
80
DALI-2
270x240
775A
New
4350
42
A60
2200
70
DALI-2
270x240
767A
New
4550
42.4
A60
3000
80
DALI-2
270x240
771A
New
3440
28.6
ST1
4000
80
DALI-2
270x240
761A
New
3130
28.6
ST1
2200
70
DALI-2
270x240
753A
New
3270
28.9
ST1
3000
80
DALI-2
270x240
757A
New
4850
42
ST1
4000
80
DALI-2
270x240
773A
New
4410
42
ST1
2200
70
DALI-2
270x240
765A
New
4610
42.4
ST1
3000
80
DALI-2
270x240
769A
New
3070
28.6
ST1.5
4000
80
DALI-2
270x240
762A
New
2790
28.6
ST1.5
2200
70
DALI-2
270x240
754A
New
2920
28.9
ST1.5
3000
80
DALI-2
270x240
758A
New
4330
42
ST1.5
4000
80
DALI-2
270x240
774A
New
3940
42
ST1.5
2200
70
DALI-2
270x240
766A
New
4120
42.4
ST1.5
3000
80
DALI-2
270x240
770A
New
3260
28.6
STCy0.5
4000
80
DALI-2
270x240
760A
New
2960
28.6
STCy0.5
2200
70
DALI-2
270x240
752A
New
3100
28.9
STCy0.5
3000
80
DALI-2
270x240
756A
New
4590
42
STCy0.5
4000
80
DALI-2
270x240
772A
New
4170
42
STCy0.5
2200
70
DALI-2
270x240
764A
New
4370
42.4
STCy0.5
3000
80
DALI-2
270x240
768A
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3670
28.6
A60
4000
80
DALI-2
270x240
787A
New
3340
28.6
A60
2200
70
DALI-2
270x240
779A
New
3490
28.9
A60
3000
80
DALI-2
270x240
783A
New
5180
42
A60
4000
80
DALI-2
270x240
799A
New
4710
42
A60
2200
70
DALI-2
270x240
791A
New
4930
42.4
A60
3000
80
DALI-2
270x240
795A
New
3810
28.6
ST1
4000
80
DALI-2
270x240
785A
New
3470
28.6
ST1
2200
70
DALI-2
270x240
777A
New
3630
28.9
ST1
3000
80
DALI-2
270x240
781A
New
5380
42
ST1
4000
80
DALI-2
270x240
797A
New
4890
42
ST1
2200
70
DALI-2
270x240
789A
New
5110
42.4
ST1
3000
80
DALI-2
270x240
793A
New
3490
28.6
ST1.5
4000
80
DALI-2
270x240
786A
New
3170
28.6
ST1.5
2200
70
DALI-2
270x240
778A
New
3320
28.9
ST1.5
3000
80
DALI-2
270x240
782A
New
4920
42
ST1.5
4000
80
DALI-2
270x240
798A
New
4470
42
ST1.5
2200
70
DALI-2
270x240
790A
New
4680
42.4
ST1.5
3000
80
DALI-2
270x240
794A
New
3670
28.6
STCy0.5
4000
80
DALI-2
270x240
784A
New
3340
28.6
STCy0.5
2200
70
DALI-2
270x240
776A
New
3490
28.9
STCy0.5
3000
80
DALI-2
270x240
780A
New
5180
42
STCy0.5
4000
80
DALI-2
270x240
796A
New
4710
42
STCy0.5
2200
70
DALI-2
270x240
788A
New
4930
42.4
STCy0.5
3000
80
DALI-2
270x240
792A
iPro
See Overview
iPro □ 192mm
44 code(s)
□ 192 - C.o.B. - Optibeam Reflector
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
6609.6
59.2
M 17° / 16°
4000
80
DALI-2
192x192x200
EP88
New
6455.7
59.2
M 17° / 16°
3000
80
DALI-2
192x192x200
EP89
New
2800
27.2
F 28°
Tunable White
DALI-2
192x192x200
EP96
New
2800
27.2
F 28°
Tunable White
DMX-RDM
192x192x200
EP99
New
3304.8
26.6
F 32°
4000
80
DALI-2
192x192x200
EP76
New
3159
26.6
F 32°
3000
80
DALI-2
192x192x200
EP77
New
5232.6
45.3
F 32°
4000
80
DALI-2
192x192x200
EP82
New
5111.1
45.3
F 32°
3000
80
DALI-2
192x192x200
EP83
New
6609.6
59.2
F 32°
4000
80
DALI-2
192x192x200
EP90
New
6455.7
59.2
F 32°
3000
80
DALI-2
192x192x200
EP91
New
2835
27.2
WF 40°
Tunable White
DALI-2
192x192x200
EP97
New
2835
27.2
WF 40°
Tunable White
DMX-RDM
192x192x200
EQ01
New
3304.8
26.6
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP78
New
3159
26.6
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP79
New
5232.6
45.3
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP84
New
5111.1
45.3
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP85
New
6609.6
59.2
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP92
New
6455.7
59.2
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP93
New
3264
26.6
VWF 82°
4000
80
DALI-2
192x192x200
EP80
New
3120
26.6
VWF 82°
3000
80
DALI-2
192x192x200
EP81
New
2940
27.2
VWF 82°
Tunable White
DALI-2
192x192x200
EP98
New
2940
27.2
VWF 82°
Tunable White
DMX-RDM
192x192x200
EQ02
New
5168
45.3
VWF 82°
4000
80
DALI-2
192x192x200
EP86
New
5048
45.3
VWF 82°
3000
80
DALI-2
192x192x200
EP87
New
6528
59.2
VWF 82°
4000
80
DALI-2
192x192x200
EP94
New
6376
59.2
VWF 82°
3000
80
DALI-2
192x192x200
EP95
Complete with power supply. DALI versions occupy 1 address.
iPro □ 192 floodlights can be wall-mounted using the special base BZM5.
□ 192 - C.o.B. - Optibeam Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
725
14.1
SS 6°
4000
80
DALI-2
192x192x225
EP72
New
696
14.1
SS 6°
3000
80
DALI-2
192x192x225
EP73
New
1351.1
18.3
S 10°
4000
80
DALI-2
192x192x200
EP74
New
1333.4
18.3
S 10°
3000
80
DALI-2
192x192x200
EP75
□ 192 - C.o.B. - Opti Smart Reflector
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3442.5
33.2
A60
4000
80
DALI-2
192x192x200
EQ03
New
3442.5
33.2
A60
3000
80
DALI-2
192x192x200
EQ04
Recommended pole application
□ 192 - C.o.B. - Opti Smart Reflector
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3847.5
33.2
ST1
4000
70
DALI-2
192x192x200
EQ05
New
3523.5
33.2
ST1
3000
70
DALI-2
192x192x200
EQ06
Recommended pole application
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3280
31.1
S 12° / 10°
4000
80
DALI-2
192x192x200
BG35
New
3280
31.1
S 12° / 10°
3000
80
DALI-2
192x192x200
BG36
New
2920
31.1
M 20°
4000
80
DALI-2
192x192x200
BG37
New
2920
31.1
M 20°
3000
80
DALI-2
192x192x200
BG38
Complete with power supply
iPro □ 192 floodlights can be wall-mounted using the special base BZM5.
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
945.5
21.2
S 12°
RGB
DMX-RDM
192x192x200
BV60
New
883.5
21.2
F 28° / 30°
RGB
DMX-RDM
192x192x200
BV61
Complete with power supply and electronic DMX512-RDM control card. DMX specifications require the insertion of a 120 Ohm terminating resistor (code BZQ7) to be placed between the DATA+ and DATA- cables of the last product in the line.
iPro floodlights □ 192 can be wall-mounted using the special base BZM5.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3239
33.8
S 12° / 10°
Tunable White
80
DMX-RDM
192x192x200
BV62
New
2844
33.8
F 34°
Tunable White
80
DMX-RDM
192x192x200
BV63
Tunable white: 2700K÷6000K
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
1457.5
31
S 12° / 10°
RGBW - 4000K
DMX-RDM
192x192x200
JNN1
New
1265
31
F 38°
RGBW - 4000K
DMX-RDM
192x192x200
JNN2
Complete with power supply and electronic DMX512-RDM control card. DMX specifications require the insertion of a 120 Ohm terminating resistor (code BZQ7) to be placed between the DATA+ and DATA- cables of the last product in the line.
iPro floodlights □ 192 can be wall-mounted using the special base BZM5.
iPro □ 192mm wall mounted
34 code(s)
□ 192 - C.o.B. - Optibeam Reflector
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
6609.6
59.2
M 17° / 16°
4000
80
DALI-2
192x192x200
EP88
New
6455.7
59.2
M 17° / 16°
3000
80
DALI-2
192x192x200
EP89
New
2800
27.2
F 28°
Tunable White
DALI-2
192x192x200
EP96
New
2800
27.2
F 28°
Tunable White
DMX-RDM
192x192x200
EP99
New
3304.8
26.6
F 32°
4000
80
DALI-2
192x192x200
EP76
New
3159
26.6
F 32°
3000
80
DALI-2
192x192x200
EP77
New
5232.6
45.3
F 32°
4000
80
DALI-2
192x192x200
EP82
New
5111.1
45.3
F 32°
3000
80
DALI-2
192x192x200
EP83
New
6609.6
59.2
F 32°
4000
80
DALI-2
192x192x200
EP90
New
6455.7
59.2
F 32°
3000
80
DALI-2
192x192x200
EP91
New
2835
27.2
WF 40°
Tunable White
DALI-2
192x192x200
EP97
New
2835
27.2
WF 40°
Tunable White
DMX-RDM
192x192x200
EQ01
New
3304.8
26.6
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP78
New
3159
26.6
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP79
New
5232.6
45.3
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP84
New
5111.1
45.3
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP85
New
6609.6
59.2
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP92
New
6455.7
59.2
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP93
New
3264
26.6
VWF 82°
4000
80
DALI-2
192x192x200
EP80
New
3120
26.6
VWF 82°
3000
80
DALI-2
192x192x200
EP81
New
2940
27.2
VWF 82°
Tunable White
DALI-2
192x192x200
EP98
New
2940
27.2
VWF 82°
Tunable White
DMX-RDM
192x192x200
EQ02
New
5168
45.3
VWF 82°
4000
80
DALI-2
192x192x200
EP86
New
5048
45.3
VWF 82°
3000
80
DALI-2
192x192x200
EP87
New
6528
59.2
VWF 82°
4000
80
DALI-2
192x192x200
EP94
New
6376
59.2
VWF 82°
3000
80
DALI-2
192x192x200
EP95
Complete with power supply. DALI versions occupy 1 address.
iPro □ 192 floodlights can be wall-mounted using the special base BZM5.
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3280
31.1
S 12° / 10°
4000
80
DALI-2
192x192x200
BG35
New
3280
31.1
S 12° / 10°
3000
80
DALI-2
192x192x200
BG36
New
2920
31.1
M 20°
4000
80
DALI-2
192x192x200
BG37
New
2920
31.1
M 20°
3000
80
DALI-2
192x192x200
BG38
Complete with power supply
iPro □ 192 floodlights can be wall-mounted using the special base BZM5.
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
945.5
21.2
S 12°
RGB
DMX-RDM
192x192x200
BV60
New
883.5
21.2
F 28° / 30°
RGB
DMX-RDM
192x192x200
BV61
Complete with power supply and electronic DMX512-RDM control card. DMX specifications require the insertion of a 120 Ohm terminating resistor (code BZQ7) to be placed between the DATA+ and DATA- cables of the last product in the line.
iPro floodlights □ 192 can be wall-mounted using the special base BZM5.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3239
33.8
S 12° / 10°
Tunable White
80
DMX-RDM
192x192x200
BV62
New
2844
33.8
F 34°
Tunable White
80
DMX-RDM
192x192x200
BV63
Tunable white: 2700K÷6000K
MultiPro pole mounted
4 code(s)
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3280
31.1
S 12° / 10°
4000
80
DALI-2
192x192x200
BG35
New
3280
31.1
S 12° / 10°
3000
80
DALI-2
192x192x200
BG36
New
2920
31.1
M 20°
4000
80
DALI-2
192x192x200
BG37
New
2920
31.1
M 20°
3000
80
DALI-2
192x192x200
BG38
Complete with power supply
iPro □ 192 floodlights can be wall-mounted using the special base BZM5.
MultiPro wall mounted
4 code(s)
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3280
31.1
S 12° / 10°
4000
80
DALI-2
192x192x200
BG35
New
3280
31.1
S 12° / 10°
3000
80
DALI-2
192x192x200
BG36
New
2920
31.1
M 20°
4000
80
DALI-2
192x192x200
BG37
New
2920
31.1
M 20°
3000
80
DALI-2
192x192x200
BG38
Complete with power supply
iPro □ 192 floodlights can be wall-mounted using the special base BZM5.
MultiPro minimal and connected pole
44 code(s)
□ 192 - C.o.B. - Optibeam Reflector
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
6609.6
59.2
M 17° / 16°
4000
80
DALI-2
192x192x200
EP88
New
6455.7
59.2
M 17° / 16°
3000
80
DALI-2
192x192x200
EP89
New
2800
27.2
F 28°
Tunable White
DALI-2
192x192x200
EP96
New
2800
27.2
F 28°
Tunable White
DMX-RDM
192x192x200
EP99
New
3304.8
26.6
F 32°
4000
80
DALI-2
192x192x200
EP76
New
3159
26.6
F 32°
3000
80
DALI-2
192x192x200
EP77
New
5232.6
45.3
F 32°
4000
80
DALI-2
192x192x200
EP82
New
5111.1
45.3
F 32°
3000
80
DALI-2
192x192x200
EP83
New
6609.6
59.2
F 32°
4000
80
DALI-2
192x192x200
EP90
New
6455.7
59.2
F 32°
3000
80
DALI-2
192x192x200
EP91
New
2835
27.2
WF 40°
Tunable White
DALI-2
192x192x200
EP97
New
2835
27.2
WF 40°
Tunable White
DMX-RDM
192x192x200
EQ01
New
3304.8
26.6
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP78
New
3159
26.6
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP79
New
5232.6
45.3
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP84
New
5111.1
45.3
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP85
New
6609.6
59.2
WF 46° / 47°
4000
80
DALI-2
192x192x200
EP92
New
6455.7
59.2
WF 46° / 47°
3000
80
DALI-2
192x192x200
EP93
New
3264
26.6
VWF 82°
4000
80
DALI-2
192x192x200
EP80
New
3120
26.6
VWF 82°
3000
80
DALI-2
192x192x200
EP81
New
2940
27.2
VWF 82°
Tunable White
DALI-2
192x192x200
EP98
New
2940
27.2
VWF 82°
Tunable White
DMX-RDM
192x192x200
EQ02
New
5168
45.3
VWF 82°
4000
80
DALI-2
192x192x200
EP86
New
5048
45.3
VWF 82°
3000
80
DALI-2
192x192x200
EP87
New
6528
59.2
VWF 82°
4000
80
DALI-2
192x192x200
EP94
New
6376
59.2
VWF 82°
3000
80
DALI-2
192x192x200
EP95
Complete with power supply. DALI versions occupy 1 address.
iPro □ 192 floodlights can be wall-mounted using the special base BZM5.
□ 192 - C.o.B. - Optibeam Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
725
14.1
SS 6°
4000
80
DALI-2
192x192x225
EP72
New
696
14.1
SS 6°
3000
80
DALI-2
192x192x225
EP73
New
1351.1
18.3
S 10°
4000
80
DALI-2
192x192x200
EP74
New
1333.4
18.3
S 10°
3000
80
DALI-2
192x192x200
EP75
□ 192 - C.o.B. - Opti Smart Reflector
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3442.5
33.2
A60
4000
80
DALI-2
192x192x200
EQ03
New
3442.5
33.2
A60
3000
80
DALI-2
192x192x200
EQ04
Recommended pole application
□ 192 - C.o.B. - Opti Smart Reflector
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3847.5
33.2
ST1
4000
70
DALI-2
192x192x200
EQ05
New
3523.5
33.2
ST1
3000
70
DALI-2
192x192x200
EQ06
Recommended pole application
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3280
31.1
S 12° / 10°
4000
80
DALI-2
192x192x200
BG35
New
3280
31.1
S 12° / 10°
3000
80
DALI-2
192x192x200
BG36
New
2920
31.1
M 20°
4000
80
DALI-2
192x192x200
BG37
New
2920
31.1
M 20°
3000
80
DALI-2
192x192x200
BG38
Complete with power supply
iPro □ 192 floodlights can be wall-mounted using the special base BZM5.
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
945.5
21.2
S 12°
RGB
DMX-RDM
192x192x200
BV60
New
883.5
21.2
F 28° / 30°
RGB
DMX-RDM
192x192x200
BV61
Complete with power supply and electronic DMX512-RDM control card. DMX specifications require the insertion of a 120 Ohm terminating resistor (code BZQ7) to be placed between the DATA+ and DATA- cables of the last product in the line.
iPro floodlights □ 192 can be wall-mounted using the special base BZM5.
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
3239
33.8
S 12° / 10°
Tunable White
80
DMX-RDM
192x192x200
BV62
New
2844
33.8
F 34°
Tunable White
80
DMX-RDM
192x192x200
BV63
Tunable white: 2700K÷6000K
□ 192 - Multi Chip Lens
lm system
W system
Optic
K
CRI
Control
Size (mm)
Code
New
1457.5
31
S 12° / 10°
RGBW - 4000K
DMX-RDM
192x192x200
JNN1
New
1265
31
F 38°
RGBW - 4000K
DMX-RDM
192x192x200
JNN2
Complete with power supply and electronic DMX512-RDM control card. DMX specifications require the insertion of a 120 Ohm terminating resistor (code BZQ7) to be placed between the DATA+ and DATA- cables of the last product in the line.
iPro floodlights □ 192 can be wall-mounted using the special base BZM5.
updated
Downloads
Documentation:
Pole-mounted product compositions
Specification sheet
Specification text
Installation instructions
Download zip
Photometric data (.ies / .ldt / Dialux / Relux):
Download zip
3D BIM Revit:
3D BIM Revit
Download zip
2D/3D drawings (.dwg / .max):
2D
3D
Download zip
Certifications:
CE
Download zip
Software & documentation:
Download zip
Download All
Do you want to know more?
Make Enquiry
5 year product warranty included
Sign in
Staff Sign In
Email address*
Email address*
Password*